where does Dynare store parameters with the pound operator?

This forum is closed. You can read the posts but cannot write. We have migrated the forum to a new location where you will have to reset your password.
Forum rules
This forum is closed. You can read the posts but cannot write. We have migrated the forum to a new location (https://forum.dynare.org) where you will have to reset your password.

where does Dynare store parameters with the pound operator?

Postby Lara » Sun Feb 02, 2014 6:43 pm

Dear all,
I am estimating a linearized model using the pound operator (#) for some parameters. Where does Dynare store those parameters (updated once the estimation is done)? If for example #gamma = 1 + ctrend/100, where can I read the updated value of gamma?
Thanks in advance for your help.
Lara
Lara
 
Posts: 33
Joined: Tue Jan 19, 2010 7:11 pm

Re: where does Dynare store parameters with the pound operat

Postby jpfeifer » Sun Feb 02, 2014 7:42 pm

Dynare does not store it at all. Given the estimated parameters, you would have to compute it using the specified formula. The reason for not storing it is that this would be redundant as the defined expression is not an independent parameter.
------------
Johannes Pfeifer
University of Cologne
https://sites.google.com/site/pfeiferecon/
jpfeifer
 
Posts: 6940
Joined: Sun Feb 21, 2010 4:02 pm
Location: Cologne, Germany